Chinese Journal of Industrial Hygiene and Occupational Diseases ; (12): 396-400, 2022.
Artigo em Chinês | WPRIM | ID: wpr-935820

RESUMO

There are many occupational risk factors in operating room work. Polymethyl methacrylate (PMMA) , as a kind of common bone filling and repairing material, is widely used in the fixation of artificial joints, oral braces and orthopedic prosthesis. However, PMMA will release methyl methacrylate (MMA) monomer when it is implanted into human tissues and polymerized to harden, which is toxic to the body. This paper analyzes harmful factors in using PMMA bone cement, and then explores corresponding occupational protection knowledge, in order to reduce the occurrence of occupational hazards related to PMMA bone cement and enhance the self-protection ability of the operation room medical staff.


Assuntos
Humanos , Cimentos Ósseos/efeitos adversos , Salas Cirúrgicas , Polimetil Metacrilato/efeitos adversos
2.
J. bras. nefrol ; 43(2): 288-292, Apr.-June 2021. tab, graf
Artigo em Inglês, Português | LILACS | ID: biblio-1286930

RESUMO

Abstract Cosmetic injections of fillers are common plastic surgery procedures worldwide. Polymethylmethacrylate (PMMA) is a filler approved only for minimally invasive procedures in facial tissue and is among the most frequently used injectable substances for cosmetic purposes. Injection of a large volume of PMMA may lead to the development of severe hypercalcemia and chronic kidney damage in a probably underestimated frequency. In such cases, hypercalcemia develops due to a granulomatous foreign body reaction with extrarenal production of calcitriol. In the present report, we describe the cases of two patients who received injections of large volumes of PMMA and developed severe hypercalcemia and advanced chronic kidney disease. These reports highlight the importance of adhering to regulations regarding the use of PMMA and properly informing patients of the possibility of complications before undertaking such procedures.


Resumo Injeções de preenchimento de caráter estético são procedimentos comuns em cirurgia plástica em todo o mundo. O polimetilmetacrilato (PMMA) é um material de preenchimento aprovado apenas para procedimentos minimamente invasivos no tecido facial, e está entre as substâncias injetáveis mais frequentemente usadas para fins estéticos. A injeção de um grande volume de PMMA pode levar ao desenvolvimento de hipercalcemia grave e lesão renal crônica em uma frequência provavelmente subestimada. Nesses casos, a hipercalcemia se desenvolve devido a uma reação granulomatosa de corpo estranho, secundária à produção extrarenal de calcitriol. No presente artigo, descrevemos os casos de dois pacientes que receberam injeções de grandes volumes de PMMA e desenvolveram hipercalcemia grave e doença renal crônica avançada. Esses relatos destacam a importância de seguir as regulamentações sobre o uso do PMMA e informar adequadamente os pacientes sobre a possibilidade de complicações antes de realizar tais procedimentos.


Assuntos
Humanos , Técnicas Cosméticas , Insuficiência Renal Crônica/complicações , Hipercalcemia/induzido quimicamente , Calcitriol , Polimetil Metacrilato/efeitos adversos
3.
Rev. bras. cir. plást ; 34(1): 156-162, jan.-mar. 2019. ilus
Artigo em Inglês, Português | LILACS | ID: biblio-994624

RESUMO

Introdução: Os preenchedores permanentes, apesar de resultados duradouros, são verdadeiros problemas quando causam complicações. No Brasil, o PMMA é um produto aprovado pela Anvisa, mas seu uso extrapola suas indicações, levando a complicações graves. Há mais de uma década, existem recomendações sobre sua restrição, mas casos com consequências graves do seu uso irresponsável são atuais. Objetivo: Relatar complicação grave do uso irregular do PMMA e discutir a realidade brasileira atual baseado em determinações das entidades médicas, assim como dos órgãos reguladores. Métodos: É relatado um caso de necrose extensa da região glútea após a injeção de PMMA por profissional não qualificado e discutida a situação brasileira atual do produto com base nas entidades médicas e revisão da literatura do Brasil. Discussão: Apesar do esforço das entidades médicas, são inúmeros os casos de complicações agudas e crônicas relatados na literatura brasileira. No ano de 2016, foram registradas mais de 17 mil complicações relacionadas ao PMMA, mesmo assim, é difícil estabelecer dados epidemiológicos confiáveis, pois não há controle do número de aplicações, da qualidade do produto utilizado e da capacitação dos profissionais que o utilizam. Conclusão: No Brasil, há um número expressivo de procedimentos reparadores para correção de complicações decorrentes do uso do PMMA. A gravidade do caso relatado traz à tona a necessidade de combate à má prática por profissionais não capacitados, assim como um controle mais rigoroso da comercialização do produto por entidades reguladoras.(AU)


Introduction: Use of permanent fillers can lead to significant complications. In Brazil, polymethylmethacrylate (PMMA) is a product approved by the Agência Nacional de Vigilância Sanitária (ANVISA), but its use exceeds its indications, leading to serious complications. Recommendations for restricted use have been in place for more than a decade, but cases with serious consequences due to inappropriate use are still seen. Objective: To report a serious complication due to inappropriate use of PMMA and discuss the current status of PMMA use in Brazil based on recommendations of medical societies and regulatory agencies. Methods: This report describes a case of extensive necrosis of the gluteal region after injection of PMMA by a non-qualified practitioner; the report also reviews the literature on the current status of PMMA use in Brazil. Discussion: Despite the efforts of medical societies, acute and chronic complications are still reported in the Brazilian literature. In 2016, more than 17,000 PMMArelated complications were reported; nevertheless, reliable epidemiological data remain unavailable because the number of treatments, the quality of the product, and the training of practitioners remain unregulated. Conclusion: A significant number of repair procedures are performed in Brazil to correct complications resulting from the use of PMMA. The severity of the reported case highlights the need to combat bad practice by untrained professionals, as well as the need for greater control of PMMA marketing by regulatory agencies.(AU)


Assuntos
Humanos , Feminino , Adulto , Polimetil Metacrilato/análise , Polimetil Metacrilato/efeitos adversos , Procedimentos de Cirurgia Plástica/efeitos adversos , Necrose/diagnóstico
4.
Braz. oral res. (Online) ; 32: e31, 2018. tab, graf
Artigo em Inglês | LILACS | ID: biblio-952157

RESUMO

Abstract Polymethyl methacrylate (PMMA) has been considered a suitable material for cranioplasty. However, no consensus has been reached concerning the best material for cranioplasty with regard to minimizing complications. Thus, this systematic review and meta-analysis aimed to compare the complication rates of PMMA with those of autologous bone and titanium mesh. This review was registered with PROSPERO (CRD42016042725). Systematic searches were conducted on PubMed/MEDLINE, Scopus, and Web of Science. The focus question was, "Do PMMA prostheses used in cranioplasty have complications rates similar to those of autologous bone and titanium mesh?" A meta-analysis of complication rates was performed on the basis of dichotomous outcomes assessed by risk ratio (RR) with corresponding 95% confidence intervals (CI). From 1014 data sources, 11 articles were selected according to eligibility criteria. These articles involved 1,256 individuals and 1,278 cranioplasties using autologous bone (n = 408), PMMA (n = 379), or titanium (n = 151). The follow-up period ranged from 63 days to 54.3 months. No difference was observed between the complication rates of PMMA and autologous bone (p = 0.94; RR, 0.98; 95%CI, 0.54-1.75) or between PMMA and titanium (p = 0.38; RR, 1.59; 95%CI, 0.57-4.48). Sub-analysis of the reasons for craniotomy (trauma/non-trauma) was conducted, which revealed no significant difference (p = 0.91; RR, 0.95; 95%CI, 0.37-2.42). The meta-analysis indicated that the use of PMMA yields complication rates that are near those of autologous bone and titanium mesh.


Assuntos
Humanos , Crânio/cirurgia , Transplante Ósseo/efeitos adversos , Substitutos Ósseos/efeitos adversos , Polimetil Metacrilato/efeitos adversos , Procedimentos de Cirurgia Plástica/efeitos adversos , Titânio/efeitos adversos , Transplante Autólogo/efeitos adversos , Materiais Biocompatíveis , Resinas Acrílicas/efeitos adversos , Fatores de Risco
5.
Rev. bras. cir. plást ; 30(4): 664-667, sep.-dec. 2015. ilus
Artigo em Inglês, Português | LILACS | ID: biblio-1422

RESUMO

O uso de implantes sintéticos para o preenchimento na face pode acarretar reações adversas. Estas podem ocorrer da má técnica ou decorrentes do produto. Entre os materiais utilizados, está o polimetilmetacrilato (PMMA) na forma de microesferas. Trata-se do relato de um caso de reação nodular na face de paciente do sexo feminino, após 15 anos do uso de implante de Artecoll®, produto composto por microesferas de colágeno bovino e PMMA. Foi tratada com laser de gás carbônico. Evidenciou-se o efeito tardio provocado da aplicação de implantes sintéticos na face como o Artecoll®, os fatores limitantes para ressecção convencional com bisturi e tesoura, e a opção da utilização do laser de CO2. Destacando-se a função ablativa e precisa na remoção do tecido comprometido, a preservação dos tecidos sadios e nobres, o grande potencial hemostático e a baixa morbidade, com menor cicatriz, edema, equimose e a rápida recuperação pós-operatória.


The use of synthetic implants as dermal facial fillers may cause adverse reactions, which may occur owing to inappropriate techniques or the intrinsic nature of the product. Polymethylmetacrylate (PMMA) microspheres is one of the materials used. This is a report of a case of nodular reaction in the face of a female patient, after 15 years of Artecoll® implant use, a product composed of microspheres of bovine collagen and PMMA. She was treated with a carbon dioxide laser. The delayed effect caused by the application of synthetic implants in the face, such as Artecoll®; the limiting factors of conventional resection with a scalpel and scissors; and the option for the use of carbon dioxide laser are outlined. Highlighted are the ablative and precise functions in the removal of compromised tissue, the preservation of healthy and noble tissues, the high hemostatic potential, and low morbidity, with smaller scars, edema, ecchymosis, and rapid postoperative recovery.


Assuntos
Humanos , Feminino , Pessoa de Meia-Idade , História do Século XXI , Complicações Pós-Operatórias , Cirurgia Plástica , Atrofia Muscular , Polimetil Metacrilato , Face , Ossos Faciais , Sulco Nasogeniano , Lasers , Complicações Pós-Operatórias/cirurgia , Cirurgia Plástica/métodos , Atrofia Muscular/cirurgia , Polimetil Metacrilato/efeitos adversos , Polimetil Metacrilato/uso terapêutico , Face/cirurgia , Ossos Faciais/cirurgia , Sulco Nasogeniano/cirurgia , Lasers/efeitos adversos
6.
Braz. dent. j ; 26(3): 292-296, May-Jun/2015. tab
Artigo em Inglês | LILACS | ID: lil-751873

RESUMO

This study evaluated the abrasiveness of mechanical and combined methods of denture hygiene, by the analysis of mass loss and surface roughness. Acrylic resin specimens (Plexiglass) were brushed by a tooth brushing machine (Mavtec) with a soft brush (Tek) and water (control) or four dentifrices (Sorriso, Colgate, Polident and Corega) (Experimental groups) for 50 min, representing one year of brushing (mechanical method). After brushing, the specimens were immersed in 0.5% sodium hypochlorite simulating a daily cleaning of 20 min for one year (combined method). Distilled water (23 ºC) was employed as control. The mass loss (g) was analyzed by an analytical balance and the surface roughness (μm) by a rugosimeter. Data were subjected to ANOVA and Bonferroni test (α=0.05). Polident dentifrice showed lowest values of mass loss for both methods (mechanical: -0.0072±0.0017, combined:-0.011±0.002) and the combined method resulted in greater mass loss than the mechanical, except for Corega. For the surface roughness, after the mechanical method, the lowest values were registered for water (-0.007±0.016) and Polident (0.402±0.378); for the combined method, water (-0.063±0.013) showed the lowest values; there was no statistically significant difference between methods. It was concluded that Polident was the less abrasive dentifrice and the association between chemical and mechanical methods increased the mass loss but did not change the surface roughness of specimens.


Este estudo avaliou a abrasividade causada pelos métodos mecânico e combinado de higiene de próteses totais, por meio da análise da perda de massa e rugosidade de superfície. Corpos de prova de resina acrílica (Plexiglass) foram escovados em máquina de escovação (Mavtec) com escova macia (Tek) e água ou dentifrícios (Sorriso, Colgate, Polident e Corega) (Grupos Experimentais) por 50 min, simulando 1 ano de escovação (método mecânico). Após a escovação, os corpos de prova foram imersos em hipoclorito de sódio a 0,5%, simulando imersões diárias de 20 min por 1 ano (método combinado). Água destilada (23 °C) foi empregada como controle. A perda de massa foi analisada por meio de balança analítica de precisão (g) e a rugosidade de superfície por rugosímetro (μm). Os dados foram submetidos à ANOVA e teste de Bonferroni (α=0,05). Em relação à perda de massa, os menores valores foram obtidos para o Polident em ambos os métodos (mecânico: -0,0072±0,0017; combinado: -0,011±0,002) e o método combinado resultou em maior perda de massa que o método mecânico, exceto para o Corega. Para a rugosidade de superfície, após aplicação do método mecânico, os valores mais baixos foram registrados para água (-0,007±0,016) e Polident (0,402±0,378); para o método combinado, os valores mais baixos foram obtidos para água (-0,063±0,013); não houve diferença estatística entre os métodos. Conclui-se que o Polident foi o dentifrício menos abrasivo e que a associação do método químico ao método mecânico aumentou a perda de massa, porém não alterou a rugosidade de superfície dos corpos de prova.


Assuntos
Higienizadores de Dentadura , Dentaduras , Polimetil Metacrilato/efeitos adversos , Propriedades de Superfície
7.
Yonsei Medical Journal ; : 466-468, 2010.
Artigo em Inglês | WPRIM | ID: wpr-114979

RESUMO

Polymethl methacrylate (PMMA) screw reinforcement is frequently used in osteoporotic bone as well as in damaged pilot holes. However, PMMA use can be dangerous, since the amount of applied cement is uncontrolled. A 47-year-old male with traumatic cervical spondylolisthesis at C6-7 underwent anterior cervical plate fixation. During repeated drilling and tapping for false trajectory correction, a pilot hole was damaged. Although it was an unconventional method, PMMA augmentation was tried. However, PMMA was accidentally injected to the cervical spinal cord owing to lack of fluoroscopic guidance. The PMMA was surgically removed after corpectomy and durotomy. The patient had left side hemiparesis (Grade 2/5) immediately post operation. The patient improved spontaneously (Grade 4/5) except for 4th and 5th digit extension. Here, we report a rare complication of PMMA extrusion in the spinal cord during a damaged pilot hole injection, which has not previously been described.


Assuntos
Humanos , Masculino , Pessoa de Meia-Idade , Cimentos Ósseos/efeitos adversos , Parafusos Ósseos , Vértebras Cervicais/cirurgia , Polimetil Metacrilato/efeitos adversos
8.
Rev. Fac. Med. (Caracas) ; 32(2): 166-170, dic. 2009. ilus, tab
Artigo em Espanhol | LILACS | ID: lil-631568

RESUMO

El polimetil-metacrilato es un polímero de alta resistencia al impacto, ampliamente utilizado en diferentes campos de la medicina, sin embargo, aún no está clara su indicación como relleno glúteo. A pesar de su aparente inocuidad, se han presentado complicaciones durante su uso como granulomas y nódulos palpables. Se han reportado casos de embolismo pulmonar por polimetil-metacrilato posterior a vertebroplastias. Sin embargo, no se encontró reporte bibliográfico de casos de embolismo pulmonar con su uso en procedimientos estéticos. Presentamos caso de paciente femenino de 31 años de edad, quien 4 horas luego de la inyección de 500 cm3 de polimetil-metacrilato en cada región glútea, presenta disnea en reposo de aparición súbita con tos seca y palpitaciones, disminución de agudeza visual y petequias generalizadas. Se diagnostica probable embolismo pulmonar por polimetil-metacrilato y retinopatía de Purtscher. Existe similitud clínica e imaginología del caso en estudio con embolismo por silicone, y las imágenes del fondo de ojo semejan la obstrucción de pequeñas arteriolas retinianas compatibles con este diagnóstico. Se sugieren nuevas investigaciones en el uso de polimetil-metacrilato como procedimiento estético en pro de la seguridad y en beneficio de los pacientes


Polymethyl-methacrylate is a high impact resistant polymer, widely used in different medicine fields, however its indication in buttock implants is still not clear. Even though its apparent innocuity, it has presented complications like granulomas and palpable nodules. There have been reported cases of pulmonary embolism caused by polimetil-metacrilato secondary to vertebroplasties. However, there have been no bibliographic cases of pulmonary embolism due to its use in aesthetic procedures. We present a case of a woman patient of 31 years old, who 4 hours after 500 cc injection of polymethyl- Methacrylate in each buttock, presents rest dyspnea with abrupt dry cough and palpitations, reduction in visual acuity and generalized petechiae. It is diagnosed probable pulmonary embolism by polimetil-metacrilato and Purtscher retinopathy. There is a clinical and imaginological similitude between this case and silicone embolism and the images of fondoscopy are similar to those of small retinian arteriole obstruction compatible with the diagnosis. Thereby, it is suggested new investigations in the use of polymethyl-methacrylate as esthetic procedure in favor of the patient’s security and benefit


Assuntos
Humanos , Adulto , Feminino , Dispneia/patologia , Pneumopatias/patologia , Polimetil Metacrilato/efeitos adversos , Silicones/efeitos adversos , Transplante/efeitos adversos , Vertebroplastia/métodos , Cirurgia Plástica
10.
ACM arq. catarin. med ; 36(supl.1): 154-156, jun. 2007. ilus
Artigo em Português | LILACS | ID: lil-509589

RESUMO

Introdução: além das causas mais freqüentes de perdasnasais-traumaecâncer-observamososurgimento de novas situações geradoras de mutilação do nariz, requerendo adaptações à abordagem do problema. Objetivo: apresentar dois casos de reconstrução nasal após injeção de polimetilmetacrilato para preenchimento estético na face. Método: Duas pacientes submetidas à reconstrução nasal por necrose conseqüente à injeção de polimetilmetacrilato. Resultados: visibilizados nas figuras 4, 5 e 6. Discussão: o polimetilmetacrilato é uma das substâncias utilizadas na bioplastia. A necrose conseqüente à injeção do polimetilmetacrilato para fins estéticos é uma nova entidade clínica, cuja incidência é desconhecida e a fisiopatologia sujeita à discussão. Modificações na rotina de reconstrução foram necessárias em virtude das condições locais. Retalhos septais, melhor escolha para a reparação do forro, foram contraindicados por comprometimento vascular. Utilizaram-se retalhos de pele previamente enxertada, associados a enxertos de cartilagem auricular e rotação de retalho frontal paramediano, procurando-seres peitar o princípio das subunidades anatômicas. Conclusão:a necrosedesegmentos da face após a injeção de polimetilmetecrilato é uma nova entidade clínica, cuja incidência é desconhecida, acrescentando nova etiologia às perdas nasais. Os fundamentos da reconstrução de nariz devem ser aplicados,buscando-se soluções individuais que adaptem- se às peculiaridades de cada situação.


Introduction: Inaddiction to the most frequentcauses of nasal tissue lost- cancer and trauma- new situations generating the mutilation ofthen osehavearrived, requiring adaptations to the problem-solving approach. Objective:To report two cases of nasal reconstruction after polimetilmetacrilate injection for aesthetic purposes on the face. Methods: Two female patients underwent nasal reconstruction after necrosis caused by injection of polimetilmetacrilate.Discussion:Polimetilmetacrilatehave been used as a substance for inclusion. The necrosis caused by the injection of polimetilmetacrilate is a new clinical entity, with unknown incidence and ongoing discussion of its phisiopathology. Changes in the routine of the nasal reconstruction were necessary due to local conditions. Septal flaps, the first choice for lining repair, were discarted because of previous vascular damage. Cutaneous flaps made of previously grafted skin were utilized in association with cartilage grafts and rotation of a paramedian frontal flap, following anatomical subunits principles. Conclusion: The necrosis of facial segments after injection of polimetilmetacrilate is a new clinical entity, with unknown incidence, that can be added as a new etiology of nasal tissue lost. The fundaments of nasal reconstruction should be applied, looking for individual solutions wich adapt to the peculiarities of each situation.


Assuntos
Humanos , Feminino , Pessoa de Meia-Idade , Necrose , Nariz , Polimetil Metacrilato , Nariz/anormalidades , Nariz/cirurgia , Necrose/cirurgia , Necrose/reabilitação , Necrose/terapia , Polimetil Metacrilato/administração & dosagem , Polimetil Metacrilato/efeitos adversos , Polimetil Metacrilato/toxicidade
11.
Arq. neuropsiquiatr ; 62(3B): 873-874, set. 2004. ilus
Artigo em Inglês | LILACS | ID: lil-384143

RESUMO

A injeção de polimetilmetacrilato (PMMA) é prática difundida na medicina estética como medida rejuvenecedora. No entanto, a injeção facial do PMMA carreia sérios riscos, especialmente se realizada na região glabelar. Descrevemos o caso de uma mulher que imediatamente após injeção glabelar de PMMA apresentou amaurose e oftalmoplegia total, revendo ainda a literatura pertinente.


Assuntos
Feminino , Humanos , Pessoa de Meia-Idade , Cegueira/induzido quimicamente , Técnicas Cosméticas/efeitos adversos , Oftalmoplegia/induzido quimicamente , Polimetil Metacrilato/efeitos adversos , Face , Injeções Intradérmicas , Microesferas , Polimetil Metacrilato/administração & dosagem , Rejuvenescimento
12.
Arq. neuropsiquiatr ; 62(3B): 879-881, set. 2004. ilus
Artigo em Inglês | LILACS | ID: lil-384145

RESUMO

Relatamos um caso de compressão medular e radicular durante vertebroplastia percutanea transpedicular com polimetilmetacrilato (VPTP) para tratamento de fratura com compressão por osteoporose. O início súbito de dor lancinante na distribuição do 6º nervo intercostal direito, com hiperemia ao longo de seu trajeto, determinou a interrupção do procedimento. Sob sedação com narcóticos, a paciente foi levada ao CTI, sendo administrados 10mg de dexametazona por via endovenosa. Após algumas horas, ela desenvolveu paraplegia com preservação do tato, e a TC e a RM mostraram extravazamento epidural de polimetilmetacrilato com compressão medular e radicular. Descompressão cirúrgica resultou em recuperação neurológica. O cimento foi removido após ter sua espessura diminuída com o uso de broca de alta rotação, usando técnica microcirúrgica através de laminectomia ampla de tres níveis de T5 a T7. Extravazamento de cimento é comumente encontrado em VPTP, sendo assintomático na maioria das vezes. Compressão radicular pode requerer intervenção cirúrgica se não responsiva ao tratamento com corticosteróides. Compressão medular é vista com menos frequência e requer cirurgia de emergência. O cimento não adere à dura-máter e pode ser removido facilmente.


Assuntos
Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Extravasamento de Materiais Terapêuticos e Diagnósticos/complicações , Paraplegia/etiologia , Polimetil Metacrilato/efeitos adversos , Compressão da Medula Espinal/etiologia , Descompressão Cirúrgica , Fraturas Espontâneas/etiologia , Fraturas Espontâneas/terapia , Imageamento por Ressonância Magnética , Procedimentos Ortopédicos/efeitos adversos , Procedimentos Ortopédicos/métodos , Osteoporose/complicações , Polimetil Metacrilato/administração & dosagem , Compressão da Medula Espinal/cirurgia , Fraturas da Coluna Vertebral/etiologia , Fraturas da Coluna Vertebral/terapia , Tomografia Computadorizada por Raios X